Application

The instrument is designed and made as per the National  Standard of People ’ s Republic of China GB/T213-2008 and ASTM D240 Test Method for Calorific Value of coal, GB/T384-1988 Test Method for Calorific Value of Petroleum Products and Calibration  Regulation  of  People ’ s  Republic  of  China  JJG672  Oxygen  Bomb Calorimeter, as well as Shanghai enterprise standardQ/VCZK 10 XRY Series Oxygen Bomb Calorimeter.

Main technical features

1. Adopting semiconductor refrigeration to decide the refrigerating capacity according to the calorific value,the instrument can automatically adjust water temperature and keep water in a relative constant temperature range,realize the continuously and long time test requirement,and make sure the test result is correct.

2. With a electronic measuring cup itself,no need to weigh the water by manual,it can measure the water volume automatically,the repetitive error<0.4g

3. Automatically detecting the resistance of ignition filament,automatically checking the installing condition of ignition filament before test.

4.  Standard  pipeline  design,vastly  shortening  the  pipeline,and  more  reasonable pipeline design to ensure more precision of test results.

5. Adopting professional discharge water ports,more convenient and fast when the instrument drains away water or change the water.

6.  The  electronic  balance  with  communication  function  to  share  the  data  by  the

internet.

Main technical specifications

1. Power supply: AC (220±10%)V, 50 Hz

2. Total power consumption: ≤0.2kW

3. Measuring temperature range: 5℃~35℃

4. Temperature resolution:0.0001℃

5. RSD(Relative standard deviation): ≤40J/K

6. Test time period:main period:about 12 min

7. Heat capacity: (9000~11000)J/K

8. Measuring error: ±60J/g  (Benzoic acid)

9. Accuracy:Better than GB/T213-2008 “ The determination method of coal calorific

value” .

10. Pressure endurance of oxygen bomb: 20 MPa

11. Suitable environment:

Ambient temp. :(15 ~28) ℃ , Continuous repeated testing, with an environmental temperature change of  ≤ 2  ℃;

Relative humidity:  ≤85%

12. Outline dimension:650mm×450mm×450mm(L×W×H)

13. Net weight: 55kg