Home » Products » Specialized Oil Testers » Transformer Oil Testers » Dielectric Loss/Dielectric Dissipation Factor/Tan Delta Tester » Transformer Oil Dielectric Loss/Dielectric Dissipation Factor/ Volume Resistivity/Tan Delta Tester BLS-M924 (manually oil cup cleaning and oil discharge)

loading

Share to:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Transformer Oil Dielectric Loss/Dielectric Dissipation Factor/ Volume Resistivity/Tan Delta Tester BLS-M924 (manually oil cup cleaning and oil discharge)

Availability:
Quantity:
  • BLS-M924

  • BLS

  • 90278990

Functions and Features

1.High  automation,  heating,   measuring  dielectric  loss,  and   measuring resistivity can be completed at a time.

2.The three electrode type structure with an GB/T5654-2007 standard, inter electrode spacing 2mm, can eliminate stray capacitance and leakage effect on the dielectric loss test results.

3.The    instrument    uses    medium   frequency    induction    heating,    PID temperature control algorithm. This  heating  mode  has the advantages of non-contact, oil cup and heating body, uniform heating speed, convenient control, the temperature control in temperature within the preset range error. 

4.Using advanced DSP and FFT technology to ensure the stability, accuracy and reliability of the data

5.  Internal  standard  capacitor for the  SF6  charging three  pole  capacitor, dielectric loss and capacitance of the capacitor is not affected by ambient temperature, humidity, etc., so that the accuracy of the instrument after a long time to use is still guaranteed.

6. Large screen color touch screen, man-machine dialogue convenient, concise operation, clear.

7. With the lid off the high voltage, high voltage electrode cup short reminder, eliminate safety hazards, to ensure the normal operation of the safety of operating personnel and equipment.

8. With real-time clock, test date, time can be saved with the test results, display, print; equipment can display the ambient temperature, real-time detection of the test environment.

9. Automatic storage measurement data, can store 100 sets of measurement data.

10. Correction function of empty electrode cup. The capacitance and dielectric loss factor of the empty electrode cup are measured to judge the cleaning and assembling condition of the empty electrode cup. The calibration data are saved automatically to facilitate the accurate calculation of relative capacitance and DC resistivity.


Technical Parameters

Parameter

Index

Parameter

Index

measure Range

Capacitance

5pF~200pF

Resolution

Capacitance

0.01pF

Dielectric loss

0.00001~100

Dielectric loss

10-5

Resistivity

2.5MΩm~20TΩm

Resistivity

0.001M

Measure accuracy

Capacitance

0.5%+1PF

Control accuracy

±0.5℃

Dielectric loss

±(1%Reading+0.0001)

Temperature range

0~125℃

Resistivity

±10%Reading

AC voltage

AC 0~2200V

DC voltage

DC 0~600V

Ambient temperature

0~40℃

Ambient humidity

<80%RH

Working power supply

AC220V/127V±10% 50Hz/60Hz

Size

420mm*380mm*385mm


Power

100 W

Weight

25Kg