BLS-4530
BLS
90278990
I.Application
BLS-4530 Automatic Petroleum Products Carbon Residue Tester is designed and manufactured
according to National Standards GB/T17144. It is suitable for the determination of carbon residue in petroleum products.
It is suitable for carbon residue measurement of range 0.10% (m/m) ~30.0% (m/m) petroleum products . It is also suitable for petroleum products whose carbon residue value is below 0.10% (m/m) .
II.Features
1.Fully automatic control test procedures, press button once to complete the whole test, perform 12
samples simultaneously.
2.7 Inches touch screen LCD display, HMI operational interface.
3.High precision gas flow sensor, automatic regulation of Nitrogen flow. 4.Import temperature control module with stable heating rate.
5.Automatic Nitrogen protection air flow to ensure the safety and reliability of the experiment.
6.Microprocessor program control, test results can be automatically identified, automatic storage, automatic printing.
7.Precision electronic balance and host data exchange through the data transfer cable, automatic calculation, print and save (optional)
III.Main Technical Parameters
1.Power supply: AC220V, 50Hz 2.Heating power: 1000W 3.Temperature control point: 500℃±1℃ 4.Test samples: 12 5.Pressure: 0.15Mpa 6.Nitrogen source pressure: the first stage pressure 2MPa; second stage 0.5MPa 7.Nitrogen flow rate: 150mL/min~, 600mL/min automatic switching 9.Relative humidity: less than 85% 10Dimension: 630*570*760mm 11.Weight: 45.3kg |
I.Application
BLS-4530 Automatic Petroleum Products Carbon Residue Tester is designed and manufactured
according to National Standards GB/T17144. It is suitable for the determination of carbon residue in petroleum products.
It is suitable for carbon residue measurement of range 0.10% (m/m) ~30.0% (m/m) petroleum products . It is also suitable for petroleum products whose carbon residue value is below 0.10% (m/m) .
II.Features
1.Fully automatic control test procedures, press button once to complete the whole test, perform 12
samples simultaneously.
2.7 Inches touch screen LCD display, HMI operational interface.
3.High precision gas flow sensor, automatic regulation of Nitrogen flow. 4.Import temperature control module with stable heating rate.
5.Automatic Nitrogen protection air flow to ensure the safety and reliability of the experiment.
6.Microprocessor program control, test results can be automatically identified, automatic storage, automatic printing.
7.Precision electronic balance and host data exchange through the data transfer cable, automatic calculation, print and save (optional)
III.Main Technical Parameters
1.Power supply: AC220V, 50Hz 2.Heating power: 1000W 3.Temperature control point: 500℃±1℃ 4.Test samples: 12 5.Pressure: 0.15Mpa 6.Nitrogen source pressure: the first stage pressure 2MPa; second stage 0.5MPa 7.Nitrogen flow rate: 150mL/min~, 600mL/min automatic switching 9.Relative humidity: less than 85% 10Dimension: 630*570*760mm 11.Weight: 45.3kg |