BLS-2386
BLS
90278990
I. Application
The instrument is designed and manufactured according to national petrochemical industry standard SH/T0090-91 Engine Coolant Freezing Point Determination Method and ASTM D1177, and GB/T 2430 Jet Fuel Freezing Point Measurement Method and ASTM D2386, suitable for measuring the freezing point of engine coolant and its concentrate.
II. Features
Embedded system design, imported PT100 temperature sensor, automatic whole operation process; color touch screen; can store test results; can view historical data; results print on the instrument, mechanical automatic stirring, experimental results exported through U disk available.
III. Technical Parameters
1. Working power supply: AC220V±10%; 50Hz.
2. Working cold tank: Double-layer vacuum glass bath.
3. Cold tank temperature control: +30 ℃~ -70℃ . (customized +20℃ ~ -80℃)
4. Temperature control accuracy: ±0.5℃ .
5. Bath liquid stirring: automatic stirring motor, 6W, 1200r/min.
6. Refrigeration system: Imported cascade refrigeration compressor.
7. Stirring of sample: Synchronous geared motor, 60 times/min.
8.Ambient temperature: ≤ 30℃ .
9. Relative humidity: ≤ 85%.
10. Total power consumption: about 1500W.
11. Applicable standards: SH/T0090-91, GB/T 2430, ASTM D1177, ASTM D2386
I. Application
The instrument is designed and manufactured according to national petrochemical industry standard SH/T0090-91 Engine Coolant Freezing Point Determination Method and ASTM D1177, and GB/T 2430 Jet Fuel Freezing Point Measurement Method and ASTM D2386, suitable for measuring the freezing point of engine coolant and its concentrate.
II. Features
Embedded system design, imported PT100 temperature sensor, automatic whole operation process; color touch screen; can store test results; can view historical data; results print on the instrument, mechanical automatic stirring, experimental results exported through U disk available.
III. Technical Parameters
1. Working power supply: AC220V±10%; 50Hz.
2. Working cold tank: Double-layer vacuum glass bath.
3. Cold tank temperature control: +30 ℃~ -70℃ . (customized +20℃ ~ -80℃)
4. Temperature control accuracy: ±0.5℃ .
5. Bath liquid stirring: automatic stirring motor, 6W, 1200r/min.
6. Refrigeration system: Imported cascade refrigeration compressor.
7. Stirring of sample: Synchronous geared motor, 60 times/min.
8.Ambient temperature: ≤ 30℃ .
9. Relative humidity: ≤ 85%.
10. Total power consumption: about 1500W.
11. Applicable standards: SH/T0090-91, GB/T 2430, ASTM D1177, ASTM D2386